A full range of alkaline electrolysers as well as pressurised?and gas treatment equipment.
Release Date:2023-03-20 14:21:46
1.The parts of the plant:main equipment, auxiliary equipment and electric control equipment.
2.The parts of the main equipment:electrolytic cell, auxiliary equipment integration framework.
3.The parts of the auxiliary equipment:feed water tank,lye tank,feed water pump and the hydrogen frame for reducing pressure and distribution.
4.The parts of the electric control equipment: rectifier panel, control panel, distribution cabinet.
5.Features: The plant is designed specifically for power plant. Electrolyzer, gas-liquid treatment and hydrogen drying equipment are installed in a unit,so that occupying a smaller space. The product has high hydrogen purity and low humidity. It has a high level automation, and the plant could be started and shut down automatically by pressing the button.
Overall Dimension Of Drying Integration Hydrogen Generating Plants For Power Plant
The plant consists of one block hydrogen generating plant,the frame for hydrogen reducing pressure and distributing,control Panel,rectifier,transformer,feed water pump,feed water tank, Lye tank, analysis instruments.
I pneumatic combined instruments control;II electric instruments control;III PLC control;
IV FCS (Field Bus Control System).
The Plant integrated With Water Electrolvsis Hydrogen Generating and Drying For Power Plant | ||||
model | Component Name | length(mm) | width(mm) | height(mm) |
DQ-5/3.2 | frame I Frame I | 3000 | 2000 | 2150 |
frame II Frame II | 1740 | 1100 | 270(thick) | |
frame III Frame III | 1500 | 1100 | 1500 | |
DQ-10/3.2 | frame I Frame I | 3000 | 2000 | 2450 |
frame II Frame II | 1800 | 1700 | 270(thick) | |
frame III Frame III | 1740 | 1100 | 1360 |
Main technical indicators of integrated hydrogen production and drying device for power plants | ||||||||
model | Hydrogen production m3/h | Oxygen production m3/h | Operating pressure MPa | Hydrogen purity % | Hydrogen dew point ℃ | DC power consumption | Tank overhaul cycle (year) | control mode |
Kw-h/m3H2 | ||||||||
DQ-5/3.2 | 5 | 2.5 | 3.2 | ≥99.8 | ≤-50 | ≤4.9 | 5月10日 | I II III IV |
DQ-10/3.2 | 10 | 5 | 3.2 | ≥99.8 | ≤-50 | ≤4.9 | 5月10日 | I II III IV |